Datasheet excerpt: Technical data of  OIT500-F113-B12-CB3

Product Description
Optical high temperature identification system, 300  to  450 mm
General specifications
Light sourceIntegrated LED lightning
Light typeinfrared
SymbologiesCB1: perforated matrix 6 x 6 6 decimal digits
CB3: hole pattern 3 x 12 12 binary digits
Read distanceCB1: 300 ... 450 mm
CB3: 350 ... 400 mm
Reading field340 mm x 210 mm at max. read distance
Evaluation frequency5 Hz
Target velocitytriggered max. 1.5 m/s
Functional safety related parameters
MTTFd51 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green: supply
LED green: ready
Function indicatorYellow LED: trigger
Yellow LED: code read
Red LED: pre-fault
Red LED: group error
Electrical specifications
Operating voltage24 V DC ± 15% , PELV
Operating current250 mA without output drivers
Interface
Physical Ethernet
ProtocolTCP/IP
Transfer rate100 MBit/s
Input
Input voltage24 V ± 15% PELV
Number/Type1 trigger input
3 control unit inputs
Input currentapprox. 1 mA at 24 V DC
Output
Number/Type1 conventional electronic output, PNP
Switching voltage24 V ± 15 % PELV
Switching current100 mA each output
Conformity
Shock resistanceEN 60068-2-27:2009
Vibration resistanceEN 60068-2-6:2008
Emitted interferenceEN 61000-6-4:2007+A1:2011
Noise immunityEN 61326-1:2013
Photobiological safetyEN 62471:2008 exempt group
Approvals and certificates
CE conformityCE
Ambient conditions
Ambient temperature0 ... 45 °C (32 ... 113 °F)
Storage temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP64
Connection8-pin Harting HAN
RJ-45
2 x 5-pin M12 socket
Material
Housingdiecast aluminum powder coated
Massapprox. 4000 g
Dimensions
Height101 mm
Width261 mm
Depth171 mm

Classifications

SystemClasscode
ECLASS 13.027280103
ECLASS 12.027280103
ECLASS 11.027280103
ECLASS 10.0.127280103
ECLASS 9.027280103
ECLASS 8.027280103
ECLASS 5.127280103
ETIM 9.0EC002999
ETIM 8.0EC002999
ETIM 7.0EC002999
ETIM 6.0EC002999
ETIM 5.0EC002999
UNSPSC 12.143211701

Details: OIT500-F113-B12-CB3

The OIT500-* stationary read device is an optical identification system that works using industrial vision methods and is used in automated manufacturing processes. The ambient conditions in automobile construction in particular, for example the cyclical temperature changes, often make the use of read-only tags with electronic components difficult if not impossible. For the OIT high-temperature identification system, read-only tags of solid metal plates with a perforated matrix are used, which are designed for use at temperatures of up to 500 °C and suitable for high mechanical stress.

Simple installation and commissioning without complicated, time-consuming Teach-In processes enable rapid entry. Pluggable connections for the rapid exchange of devices and a controller with simple command set via the Ethernet interface guarantee simple operation. A scratch-resistant, replaceable quartz glass panel and sturdy metal housing make the OIT500-* a robust, efficient identification system.

Datasheet: OIT500-F113-B12-CB3

DatasheetFile TypeFile Size
Datasheet OIT500-F113-B12-CB3PDF1147 KB
Fiche de données OIT500-F113-B12-CB3PDF1155 KB
Datenblatt OIT500-F113-B12-CB3PDF1151 KB
Hoja de datos OIT500-F113-B12-CB3PDF1158 KB

CAD+CAE: OIT500-F113-B12-CB3

CADFile TypeFile Size
CAD 3-D / CAD 3-DSTP1608 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZEDZ79 KB

Approvals+Certificates: OIT500-F113-B12-CB3

Declaration of ConformityFile TypeFile Size
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF34 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)PDF30 KB

Associated Products: OIT500-F113-B12-CB3

Accessories
Female cordset, Harting, 8-pin, shielded, PVC cablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Male connector RJ45 straight 4-pin, Cat5, shielded, field-attachable, insulation displacement connection, Outdoorfa
Male cordset single-ended M12 straight A-coded, 4-pin, PVC cable greyfa
Female connector, Harting, 8-pin, field attachablefa
Replacement glass for series OIT300, OIT500 and OIT1500fa
Operating software for camera-based sensorsfa
Code carrier for optical high-temperature identification system, stainless steelfa
Optical identification

From 2-D code readers and handhelds to barcode scanners and special solutions—find the ideal solution for your optical identification task.