Inductive sensor NCB2-12GM40-Z0-V1-3G-3D

NCB2-12GM40-Z0-V1-3G-3D
  • 2 mm flush
  • ATEX-/IECEx-approvals for zone 2/22 (Ex ec/tc)

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datasheet excerpt: Technical data of  NCB2-12GM40-Z0-V1-3G-3D

General specifications
Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance2 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 1.62 mm
Actual operating distance1.8 ... 2.2 mm typ.
Reduction factor rAl 0.28
Reduction factor rCu 0.23
Reduction factor r304 0.7
Output type2-wire
Nominal ratings
Operating voltage5 ... 60 V DC
Switching frequency0 ... 800 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop≤ 5 V
Operating current2 ... 100 mA
Lowest operating current2 mA
Off-state current0 ... 0.5 mA typ.
Switching state indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd2090 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level Gc (ec)IECEx TUR 21.0017X
Equipment protection level Dc (tc)IECEx TUR 21.0018X
ATEX approval
Equipment protection level Gc (ec)TÜV 20 ATEX 8523 X
Equipment protection level Dc (tc)TÜV 20 ATEX 8524 X
UL approvalcULus Listed, General Purpose
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP67
Dimensions
Length40 mm
Diameter12 mm
General information
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NCB2-12GM40-Z0-V1-3G-3D

Documents: NCB2-12GM40-Z0-V1-3G-3D

Instruction manualsFile TypeFile Size
ИнструкцииPDF181 KB
Návod k poużitíPDF173 KB
Instruktions manualPDF173 KB
Instruction manualPDF174 KB
KasutusjuhendPDF168 KB
KäyttöohjePDF168 KB
Manuel d'instructionsPDF176 KB
BetriebsanleitungPDF175 KB
Οδηγίες χρήσηςPDF184 KB
HandleidingPDF173 KB
Instruction manual / BetriebsanleitungPDF172 KB
Használati útmutatóPDF175 KB
Manuale di istruzioniPDF174 KB
Lietošanas pamācībaPDF173 KB
Instrukciju vadovasPDF174 KB
Instrukcja obsługiPDF175 KB
Manual de instruçõesPDF176 KB
Manual de utilizarePDF176 KB
Návod na poużitiePDF174 KB
Navodila za uporaboPDF172 KB
Manual de instruccionesPDF176 KB
ManualPDF171 KB
Technical information
Installation conditionsPDF1054 KB
EinbaubedingungenPDF1060 KB

CAD+CAE: NCB2-12GM40-Z0-V1-3G-3D

CADFile TypeFile Size
CAD 3-D / CAD 3-DSTP57 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
EPLAN macro EDZ / EPLAN Makro EDZEDZ65 KB

Approvals+Certificates: NCB2-12GM40-Z0-V1-3G-3D

CertificatesFile TypeFile Size
Canada USA UL Ordinary LocationPDF288 KB
Europe TUV Rheinland ATEX ec 3GPDF678 KB
Europe TUV Rheinland ATEX tc 3DPDF862 KB
Worldwide TUV Rheinland IECEx ecLINK---
Worldwide TUV Rheinland IECEx tcLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F)PDF1412 KB
ЕС декларация за съответствиеPDF1412 KB
EU Declaration of Conformity (P+F)PDF1409 KB
EU prohlášení o shoděPDF1409 KB
EU Declaration of Conformity (P+F)PDF1407 KB
EU-overensstemmelseserklæringPDF1406 KB
EU Declaration of Conformity (P+F)PDF1408 KB
EU-Declaration of conformityPDF1408 KB
UK Declaration of Conformity (P+F)PDF1381 KB
UK-Declaration of conformityPDF1381 KB
ELi vastavusdeklaratsioonPDF1406 KB
EU Declaration of Conformity (P+F)PDF1406 KB
EU Declaration of Conformity (P+F)PDF1405 KB
EU-vaatimustenmukaisuusvakuutusPDF1405 KB
Déclaration UE de conformitéPDF1406 KB
EU Declaration of Conformity (P+F)PDF1406 KB
EU-KonformitätserklärungPDF1408 KB
EU-Konformitätserklärung (P+F)PDF1408 KB
EE-Δήλωση συμμόρφωσηςPDF1412 KB
EU Declaration of Conformity (P+F)PDF1412 KB
EU Declaration of Conformity (P+F)PDF1406 KB
EU-conformiteitsverklaringPDF1405 KB
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F)PDF1406 KB
EU-Declaration of conformity / EU-KonformitätserklärungPDF1406 KB
EU Declaration of Conformity (P+F)PDF1409 KB
EU megfelelőségi nyilatkozatPDF1409 KB
Dichiarazione di conformità UEPDF1405 KB
EU Declaration of Conformity (P+F)PDF1406 KB
ES atbilstības deklarācijaPDF1406 KB
EU Declaration of Conformity (P+F)PDF1407 KB
ES atitikties deklaracijaPDF1407 KB
EU Declaration of Conformity (P+F)PDF1408 KB
Deklaracja zgodności UEPDF1408 KB
EU Declaration of Conformity (P+F)PDF1409 KB
Declaração de conformidade UEPDF1407 KB
EU Declaration of Conformity (P+F)PDF1407 KB
Declaraţia UE de conformitatePDF1407 KB
EU Declaration of Conformity (P+F)PDF1407 KB
EU Declaration of Conformity (P+F)PDF1408 KB
EÚ vyhlásenie o zhodePDF1409 KB
EU Declaration of Conformity (P+F)PDF1406 KB
Izjava EU o skladnostiPDF1406 KB
Declaración de conformidad UEPDF1406 KB
EU Declaration of Conformity (P+F)PDF1406 KB
EU Declaration of Conformity (P+F)PDF1406 KB
EU-försäkran om överensstämmelsePDF1406 KB
AB Uygunluk beyanıPDF1408 KB
EU Declaration of Conformity (P+F)PDF1408 KB

Associated Products: NCB2-12GM40-Z0-V1-3G-3D

Accessories

Mounting flange, 12 mmfa

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.